Every brewer watches the saccharometer drop day by day — but do you know what that number really tells you? This guide explains fermentation degree, apparent and real attenuation, the classic Balling 0.819 conversion, attenuation limits, and the final attenuation test that reveals a sluggish fermentation before it ruins your beer.
During primary fermentation, yeast decomposes and consumes the fermentable sugars in wort, producing ethanol, CO₂ and a range of other metabolites. Because alcohol and dissolved extract change the density of the liquid in different directions, the extract concentration of the wort falls steadily as fermentation proceeds. Fermentation degree is simply the measure of how far that fall has gone.
In other words, can you answer this question at any moment of the fermentation: what percentage of the original extract has already been converted? That is exactly what fermentation degree tells you:
A wort of 12 °P that now reads 6 °P has a fermentation degree of (12 − 6) / 12 × 100% = 50%. Simple — but the trap hides in how you measure the “current extract.” Measure it one way and you get the apparent degree; remove the alcohol first and you get the real degree. Confuse the two and every downstream decision — centrifuge timing, tank transfer, maturation length — inherits the error.

When a hydrometer (saccharometer) is used to follow primary fermentation, the reading you get is called the apparent degree of fermentation. It is fast, cheap and done in the fermentation cellar — which is why virtually every brewery manages its tanks by apparent attenuation.
But here is the catch: alcohol is lighter than water. As ethanol accumulates, it drags the density of the beer down beyond what the true sugar depletion alone would cause. The hydrometer cannot tell sugar from alcohol — it only reads density. The result?
The apparent degree of fermentation always over-reads. Because the CO₂ produced by fermentation lowers the relative density, the decrease in extract concentration measured with a saccharometer is greater than the actual decrease. The beer looks “drier” than it truly is.
In daily practice, most breweries determine the original wort density and follow fermentation in the cellar — not the laboratory — using apparent values as the working basis for fermentation management. That is perfectly fine, as long as you know the systematic bias and correct for it when it matters.

To obtain the real (true) degree of fermentation, you must first remove the alcohol from the beer: the sample is distilled, and the residue is made back up to the original volume with water before the density is measured. What remains is the density change caused by sugar depletion alone — the true attenuation.
Repeating such a distillation for every tank is impractical, of course. Fortunately, as early as 1870, Balling established the empirical conversion factor that has served brewers ever since:
Worked example: your 12 °P wort reads an apparent attenuation of 80%. The real degree of fermentation is therefore 0.819 × 80% ≈ 65.5%, corresponding to a real extract of about 12 × (1 − 0.655) ≈ 4.1 °P — not the 2.4 °P the hydrometer suggested. One quick multiplication, and your beer’s true carbohydrate content is on the table.
The same logic runs in reverse for planning: if a recipe demands a finished real attenuation of, say, 62%, the tank-side apparent target is roughly 62 / 0.819 ≈ 76% before you may consider the beer fermented out.
| Aspect | Apparent degree of fermentation (Vₐ) | Real degree of fermentation (Vᵣ) |
|---|---|---|
| How measured | Hydrometer in the cellar, sample as-is | Distil off alcohol, restore volume with water, then measure |
| Influenced by alcohol? | Yes — alcohol lowers density, value reads too high | No — alcohol removed, reflects true sugar depletion |
| Typical use | Daily tank management, transfer decisions | Laboratory checks, excise/analysis, recipe targets |
| Example (12 °P wort) | Apparent extract 2.4 °P → Vₐ = 80% | Real extract ≈ 4.1 °P → Vᵣ ≈ 65.5% |
| Conversion | Vᵣ ≈ 0.819 × Vₐ (Balling factor, 1870) | |
Table 1Apparent vs. real degree of fermentation at a glance.
Left long enough, every well-made wort approaches a floor called the attenuation limit (发酵度极限): the fermentation degree reached when yeast has consumed essentially everything it can. For a normal pale-beer wort, the attenuation limit is around 75–85% apparent; dark beers are typically pitched with attenuation targets some 10–15% lower than pale beers.
Why does fermentation stop at all? Because wort contains more than glucose and maltose:
Brewers classify beers by their real degree of fermentation. Where does your style sit?

| Classification | Real degree of fermentation | Typical character | Typical styles |
|---|---|---|---|
| High-attenuating | ≥ 65% | Dry, crisp, lighter body; residual fermentable sugar nearly zero | Diet / light beers, dry lagers, brut-style ales |
| Medium-attenuating | ≈ 60% (around 60%) | Balanced body vs. dryness; the classic lager zone | Pale lagers, Pilsners |
| Low-attenuating | < 55% | Sweet, full, malty; appreciable residual extract | Dark beers, sweet stouts, malt-forward specials |
Table 2Beer classification by real attenuation — match the target to your style.
Alongside fermentation degree, cellars work daily with apparent attenuation — the decrease in hydrometer reading from original gravity to the current reading. In practice the two concepts are handled together: first calculate the expected degree of fermentation after attenuation is complete, then track the tank against it.
For a typical 10–12 °P pale wort, attenuation is considered complete when the apparent extract has fallen to roughly 2.3–2.7 °P — an apparent attenuation of 76–80% and, by Balling’s factor, a real attenuation near 62–66%. When the reading holds steady for 24 hours or more, primary fermentation is finished and the beer can move to maturation.
Practical tip: judge “finished” by two consecutive identical readings (e.g. 24 h apart), not by a single number. A falling reading means yeast is still working; a static reading above your target signals a potential slow fermentation — see Section 6.
Even after the tank reading goes flat, the question remains: is the beer truly finished, or has yeast merely stalled? To answer it, brewers measure the final attenuation (also called the slow or residual attenuation): how much additional fermentable extract is still hiding in the “finished” beer.
Before calculating it, you must first know roughly what is fermentable in the wort. For pale beers, brewers generally accept that a residual fermentable extract of well under 1% — commonly around 0.3–0.5% — marks the practical floor of fermentation. The classic cellar procedure runs as follows:
When the density no longer falls, the beer has hit its own attenuation limit. The gap between the tank’s actual degree of fermentation and this measured limit is the final attenuation — and the whole purpose of the test is precisely this: brewers want the actual fermentation degree to approach the attenuation limit as closely as the beer style allows. A large gap predicts refermentation, gushing or off-flavours in package; a small gap predicts stability.

Slow fermentation has many parents — and most of them are preventable:
| Symptom in the cellar | Likely root cause | Corrective action |
|---|---|---|
| Gravity stalls above target, yeast in suspension | Low FAN / zinc-poor wort, under-oxygenation | Verify malt nitrogen, add yeast nutrient, rouse with CO₂/air as appropriate |
| Reading static for days, yeast flocs early | Poor yeast vitality or wrong strain for the wort | Re-pitch fresh culture; raise temperature 1–2 °C to rouse |
| Attenuation fine in tank, refermentation in bottle | Residual fermentables + autolysed-yeast nutrients | Run the final attenuation test; tighten filtration/centrifuge and storage time |
| Wide gap between actual and limit attenuation | Fermentation stopped early — style mismatch or fault | Diagnose above causes; adjust mashing fermentability (see our mashing guides) |
Table 3Quick diagnosis checklist for slow fermentation.
The three numbers answer three different questions, and a disciplined brewery uses all of them:
Control them together and your fermentations become predictable: pitch with a target Vₐ, convert to Vᵣ for release specs, and confirm with the forced-fermentation test that the gap to the attenuation limit is within style. That is fermentation degree turned from a textbook formula into a working tool — exactly the mindset we build into ZR Brewing’s fermentation equipment.
Fermentation degree expresses how much extract has been consumed at any moment; attenuation describes the fall of the gravity reading itself. Apparent attenuation is measured with a hydrometer as-is; real attenuation is measured after removing the alcohol, so real values are always lower.
Ethanol is lighter than water. Its presence lowers the beer’s density, so the hydrometer under-reads the true extract — the sugar depletion therefore appears greater than it really is, inflating the apparent value.
It is the empirical ratio between real and apparent degree of fermentation established by Balling in 1870: Vᵣ ≈ 0.819 × Vₐ. Multiply your cellar reading by 0.819 to estimate the true attenuation without distillation.
For normal pale worts the limit lies around 75–85% apparent attenuation (roughly 61–70% real). Dark beers are usually targeted about 10–15% lower than pale beers.
By real degree of fermentation: about 60% counts as medium attenuation, 65% or above is high attenuation (dry, diet and light beers), and below about 55% is low attenuation (sweet, full-bodied dark styles).
Example: 12 °P original wort, apparent reading 2.4 °P → Vₐ = 80% → Vᵣ = 0.819 × 80% ≈ 65.5% → real extract ≈ 12 × (1 − 0.655) ≈ 4.1 °P.
To show how much fermentable extract remains and how far the beer still is from its attenuation limit. Brewers want the actual fermentation degree to approach the limit; a large gap predicts refermentation, gushing and flavour instability in package.
Yes. Autolysing yeast in fermentation and finished-beer storage vessels releases growth factors that let residual yeast consume leftover fermentable sugars — one reason long storage on yeast and insufficient final attenuation are both shelf-life risks.
Predictable attenuation starts with hardware: precise temperature control, sanitary conical geometry, complete CIP coverage and dependable yeast management. ZR Brewing manufactures stainless-steel conical fermenters, unitanks and complete fermentation systems for craft breweries and industrial lines worldwide.
Talk to our engineers about your target attenuation — we will match the tank to your beer.
24시간 이내에 답변해 드리겠습니다. 긴급한 사안이신 경우, WhatsApp/WeChat(+8613188932181)으로 연락해 주시기 바랍니다.
*당사는 귀하의 개인정보를 존중하며, 모든 정보는 안전하게 보호됩니다.
당사는 귀하의 정보를 오직 문의에 답변하는 용도로만 사용하며, 원치 않는 이메일이나 홍보 메시지를 절대 보내지 않습니다.